Chemical (CAS#)

Acetone (67-64-1)

Classification

  • Flammable Liquid

Formula

CH3COCH3

Characteristics

Clear-colorless liquid, alcohol-like

Treatment

Apply FAST-ACT powder to fully cover liquid spill and absorb excess liquid.

Mechanism/Byproduct

Absorption through C=O

Primary Mechanism Type

Absorption

Byproduct

Compound mixed with MgO, TiO2, Mg(OH)2

Disposal Notes

Evaluate for Paint Filter Test + Evaluate for Flash Point + Dispose in Landfill if Characteristic Hazard Does Not Exist

Reaction Rate (Slower to Faster)

Reaction Rate: 2.5

Summary




FAST-ACT Application Methods:

Situations:

A. For trace liquid chemical contamination, apply FAST-ACT Powder from either a shaker or pail to the surface to fully absorb the compounds. Apply powder forming a ring around the hazard and then shake the powder directly onto hazard to thoroughly cover the liquid. Carefully Agitate all the powder to ensure all liquid has been adsorbed.

B.Alternatively, for trace contamination on a surface, you can utilize a FAST-ACT Decon Mitt. Tear packet at the notch and remove the FAST-ACT Decon Mitt. Unfold mitt and insert hand, tightening the strap. Decontaminate surface by rubbing with pad side to remove liquid contamination. Shake and pat the mitt to release powder from the mitt to the surface. If liquid contamination is still present or suspected, repeat process with a new FAST-ACT Decon Mitt.

C.For liquid contamination, directly apply the FAST-ACT Powder from a Shaker or Pail to the liquid to fully absorb the compound ensuring no liquid chemical remains. Apply powder forming a ring around the hazard and then shake the powder directly onto hazard to thoroughly cover the liquid. Carefully agitate all the powder to ensure all liquid has been adsorbed.